Stucco transition150 viewsProper transition from stucco exterior to stone exterior.
|
|

Moisture intrusion103 viewsRunoff from the chimney is directed to the top of the window, where moisture intrusion is evident by stains below the window. Kick out flashing at the shoulder of the chimney, which directs run off away from the window, may have helped.
|
|

No stucco termination.155 viewsIn this photo, stucco is failing because it is not terminated at the foundation. The stucco covers the slab, which expands and contracts at a different rate than the rest of the wall, creating cracks. No previsions have been made to ventilate the wall behind the stucco or to provide an exit for any moisture that gets behind the stucco facade.
|
|

Exterior in contact with grade102 viewsGrade level (the ground) on this commercial building is in contact with the stucco siding, allowing moisture to wick up into the wall cavities and inhibit ventilation of the stucco wall.
|
|

Stucco/Masonry transition105 viewsProper stucco/masonry transition
|
|
|
|
|
| Last additions |

No stucco termination.155 viewsIn this photo, stucco is failing because it is not terminated at the foundation. The stucco covers the slab, which expands and contracts at a different rate than the rest of the wall, creating cracks. No previsions have been made to ventilate the wall behind the stucco or to provide an exit for any moisture that gets behind the stucco facade.Oct 13, 2009
|
|

Moisture intrusion103 viewsRunoff from the chimney is directed to the top of the window, where moisture intrusion is evident by stains below the window. Kick out flashing at the shoulder of the chimney, which directs run off away from the window, may have helped.Oct 13, 2009
|
|

Exterior in contact with grade102 viewsGrade level (the ground) on this commercial building is in contact with the stucco siding, allowing moisture to wick up into the wall cavities and inhibit ventilation of the stucco wall. Oct 13, 2009
|
|

Stucco transition150 viewsProper transition from stucco exterior to stone exterior.Oct 13, 2009
|
|

Stucco/Masonry transition105 viewsProper stucco/masonry transitionOct 13, 2009
|
|
|
|
|