| Top rated |

No stucco termination.36 viewsIn this photo, stucco is failing because it is not terminated at the foundation. The stucco covers the slab, which expands and contracts at a different rate than the rest of the wall, creating cracks. No previsions have been made to ventilate the wall behind the stucco or to provide an exit for any moisture that gets behind the stucco facade. (1 votes)
|
|

Moisture intrusion44 viewsRunoff from the chimney is directed to the top of the window, where moisture intrusion is evident by stains below the window. Kick out flashing at the shoulder of the chimney, which directs run off away from the window, may have helped. (1 votes)
|
|

Exterior in contact with grade41 viewsGrade level (the ground) on this commercial building is in contact with the stucco siding, allowing moisture to wick up into the wall cavities and inhibit ventilation of the stucco wall.  (1 votes)
|
|

Stucco transition37 viewsProper transition from stucco exterior to stone exterior. (1 votes)
|
|

Stucco/Masonry transition43 viewsProper stucco/masonry transition (1 votes)
|
|
|
|
|
|
|